PRODUCT MATERIALS
Materials & testing
See the results for silicone gasket material identification, metal screening and total migration in 20% ethanol.
These results apply to the gasket samples tested. They do not cover drinking water or every finished bottle. The test table does not name the laboratory, test date or sample ID. Contact us for the full report.
| Test | Reported result | Reported assessment | LOD/LOQ | Recovery (%) | Measurement uncertainty | Instrument | Method |
|---|---|---|---|---|---|---|---|
| Material identification | Gasket 1: Silicone; Gasket 2: Silicone | Conforms | — | — | — | FT-IR | Polymer Handbook/Plastics Analysis Guide In-house method: LTS.SOP.01.193 |
| Iron (Fe) | Not detected | Conforms | 0,05 mg/kg | — | — | ICP-MS | TS EN 13130-1:2006 |
| Zinc (Zn) | Not detected | Conforms | 0,05 mg/kg | — | — | ICP-MS | TS EN 13130-1:2006 |
| Copper (Cu) | Not detected | Conforms | 0,05 mg/kg | — | — | ICP-MS | TS EN 13130-1:2006 |
| Aluminium (Al) | Not detected | Conforms | 0,05 mg/kg | — | — | ICP-MS | TS EN 13130-1:2006 |
| Manganese (Mn) | Not detected | Conforms | 0,05 mg/kg | — | — | ICP-MS | TS EN 13130-1:2006 |
| Cobalt (Co) | Not detected | Conforms | 0,005 mg/kg | — | — | ICP-MS | TS EN 13130-1:2006 |
| Total migration — 20% ethyl alcohol | <0.1 mg/dm² at 70°C for 2 hours | Conforms | — | — | — | — | TS EN 1186-3 Method 5:2022 |
| Sodium (Na) | Not detected | Conforms | 0,05 mg/kg | — | — | ICP-MS | TS EN 13130-1:2006 |
| Magnesium (Mg) | Not detected | Conforms | 0,005 mg/kg | — | — | ICP-MS | TS EN 13130-1:2006 |
| Calcium (Ca) | Not detected | Conforms | 0,05 mg/kg | — | — | ICP-MS | TS EN 13130-1:2006 |
| Potassium (K) | Not detected | Conforms | 0,05 mg/kg | — | — | ICP-MS | TS EN 13130-1:2006 |
| Chromium (Cr) | Not detected | Conforms | 0,0001 mg/kg | — | — | ICP-MS | TS EN 13130-1:2006 |
| Antimony (Sb) | Not detected | Conforms | 0,005 mg/kg | — | — | ICP-MS | TS EN 13130-1:2006 |
| Lanthanum (La) | Not detected | Conforms | 0,005 mg/kg | — | — | ICP-MS | TS EN 13130-1:2006 |
| Gadolinium (Gd) | Not detected | Conforms | 0,005 mg/kg | — | — | ICP-MS | TS EN 13130-1:2006 |
| Europium (Eu) | Not detected | Conforms | 0,005 mg/kg | — | — | ICP-MS | TS EN 13130-1:2006 |
| Terbium (Tb) | Not detected | Conforms | 0,005 mg/kg | — | — | ICP-MS | TS EN 13130-1:2006 |
| Cadmium (Cd) | Not detected | Conforms | 0,0001 mg/kg | — | — | ICP-MS | TS EN 13130-1:2006 |
| Mercury (Hg) | Not detected | Conforms | 0,0001 mg/kg | — | — | ICP-MS | TS EN 13130-1:2006 |
| Barium (Ba) | Not detected | Conforms | 0,05 mg/kg | — | — | ICP-MS | TS EN 13130-1:2006 |
| Arsenic (As) | Not detected | Conforms | 0,0001 mg/kg | — | — | ICP-MS | TS EN 13130-1:2006 |
| Lead (Pb) | Not detected | Conforms | 0,0001 mg/kg | — | — | ICP-MS | TS EN 13130-1:2006 |
| Nickel (Ni) | Not detected | Conforms | 0,0025 mg/kg | — | — | ICP-MS | TS EN 13130-1:2006 |
| Lithium (Li) | Not detected | Conforms | 0,05 mg/kg | — | — | ICP-MS | TS EN 13130-1:2006 |
A dash means no value was listed. Conformity assessments are taken from the test table.